TIM361-2134101 - 1071399
    Features
    Measurement principle	HDDM+
    Application	Outdoor
    Light source	Infrared (850 nm)
    Laser class	1 (IEC 60825-1:2014, EN 60825-1:2014)
    Aperture angle	
    Horizontal	270°
    Scanning frequency	15 Hz
    Angular resolution	0.33°
    Working range	0.05 m ... 10 m
    Scanning range	
    At 10% remission	8 m
    Mechanics/electronics
    Connection type	
    1 x “Ethernet” connection, 4-pin M12 female connector
    1 x connection “Power”, 12-pin, M12 male connector
    1 x Micro USB female connector, type B
    Supply voltage	9 V DC ... 28 V DC
    Power consumption	Typ. 4 W, 16 W with 4 max. loaded digital outputs
    Housing color	Gray (RAL 7032)
    Enclosure rating	IP67, applies only when the plastic cover of the “Aux interface” is closed (IEC 60529:1989+AMD1:1999+AMD2:2013)
    Protection class	III (IEC 61140:2016-1)
    Weight	250 g, without connecting cables
    Dimensions (L x W x H)	60 mm x 60 mm x 86 mm
    Performance
    Response time	
    1 scan, typ. 67 ms
    2 scans, ≤ 134 ms 1)
    Detectable object shape	Almost any
    Systematic error	± 60 mm 2)
    Statistical error	< 20 mm 2)
    Integrated application	Field evaluation with flexible fields
    Number of field sets	16 field triples (48 fields, contour as reference; 1 triple (3 flexible fields) can be configured directly at the scanner)
    Simultaneous evaluation cases	
    1 (3 fields)
    2 (2 fields for detection and 1 field for contour as reference)
        1) At +45° to +225° of the working range; max. 150 ms at –45° to +45° of the working range.
        2) Typical value at 90% remission up to maximum scanning range; real value depends on ambient conditions.
    Interfaces
    Ethernet	✔ , TCP/IP
    Function	AUX, parameterization
    USB	✔
    Remark	Micro USB
    Function	AUX, parameterization
    Digital inputs	4
    Digital outputs	3 (PNP, additional 1 x “Device Ready”)
    Delay time	67 ms ... 30,000 ms (configurable)
    Dwell time	67 ms ... 600,052 ms (configurable)
    Optical indicators	2 LEDs (ON, switching status)
    Ambient data
    Object remission	4 % ... 1,000 % (reflectors)
    Electromagnetic compatibility (EMC)	
    Emitted radiation	Residential area (EN 61000-6-3:2007+AMD:A1:2011)
    Electromagnetic immunity	Industrial environment (EN 61000-6-2:2005)
    Vibration resistance	
    Sine resonance scan	10 Hz ... 1,000 Hz 1)
    Sine test	10 Hz ... 500 Hz, 5 g, 10 frequency cycles 1)
    Noise test	10 Hz ... 250 Hz, 4.24 g RMS, 5 h 2)
    Shock resistance	
    50 g, 11 ms, ± 3 single shocks/axis 3)
    25 g, 6 ms, ± 1,000 continuous shocks/axis 3)
    50 g, 3 ms, ± 5,000 continuous shocks/axis 3)
    Ambient operating temperature	–25 °C ... +50 °C 4)
    Storage temperature	–40 °C ... +75 °C 4)
    Switch-on temperature	–10 °C ... +50 °C
    Temperature change	–25 °C ... +50 °C, 10 cycles 5)
    Damp heat	+25 °C ... +55 °C, 95 % rF, 6 cycles 6)
    Permissible relative humidity	
    Operation	< 80 %, Non-condensing (EN 60068-2-30:2005)
    Storage	≤ 90 %, Non-condensing (EN 60068-2-30:2005)
    Ambient light immunity	80,000 lx
        1) IEC 60068-2-6:2007.
        2) IEC 60068-2-64:2008.
        3) IEC 60068-2-27:2008.
        4) IEC 60068-2-14:2009.
        5) EN 60068-2-14:2009.
        6) EN 60068-2-30:2005.
    General notes
    Note on use	The sensor does not constitute a safety component as defined by relevant legislation on machine safety.