MPS-025CLTU0 - 1079359
    Features
    Cylinder type	C-slot
    Cylinder types with adapter	
    Round body cylinder
    Profile cylinders and tie-rod cylinders
    SMC rail CDQ2
    SMC rail ECDQ2
    Measuring range	25 mm 1)
    Housing length	41 mm
    Switching output	Push-pull: PNP/NPN
    Output function	Analog, IO-Link, Switching output
    Electrical wiring	DC 4-wire
    Analog output (voltage)	0 V ... 10 V
    Analog output (current)	4 mA ... 20 mA
    Enclosure rating	IP67 2)
    Adjustment	
    Teach-in control panel	Teaching in analog outputs
    Selecting the current/voltage output
    Inverting the analog output
    Teaching in digital switching outputs
    IO-Link	Teaching in 4 switching points
    Pin 2 configuration (0 V–10 V, 4 mA–20 mA)
    Measuring range (mm) teach-in (analog output)
    Disabling teach-in pushbutton
    Teach-in modes per output via IO-Link (cylinder switch mode, two point mode, window mode, and single point mode)
        1) ± 1 mm.
        2) According to EN 60529.
    Mechanics/electronics
    Supply voltage	12 V DC ... 30 V DC
    Power consumption	42 mA, without load
    Voltage drop	≤ 2 V
    Continuous current Ia	≤ 100 mA 1)
    Max. load resistance	≤ 500 Ω Power Output, at 24 V
    Min. load resistance	≥ 2 kΩ 2)
    Protection class	III
    Time delay before availability	0.15 s
    Required magnetic field sensitivity, typ.	3 mT ... 12 mT
    Resolution, typ.	≥ 50 µm
    Linearity error, typ.	0.3 mm 3)
    Repeat accuracy, typ.	0.1 mm 4)
    Sampling rate, typ.	1 ms
    Reverse polarity protection	Yes
    Short-circuit protection	Yes
    Status indicator LED	Yes
    Digital switching output	Yes
    Teach-in	Yes
    Ambient operating temperature	–20 °C ... +70 °C
    Shock and vibration resistance	30 g, 11 ms / 10 ... 55 Hz, 1 mm
    EMC	According to EN 60947-5-7 5)
    Connection type	Cable, 4-wire, 2 m
    Connection type Detail	
    Deep-freeze property	Do not bend below 0 °C
    Conductor cross section	0.08 mm²
    Cable diameter	Ø 2.6 mm
    Bending radius	With fixed installation > 5 x cable diameter
    	For flexible use > 10 x cable diameter
    Cable outlet	Axial
    Material	
    Housing	Plastic
    Cable	PUR
    UL File No.	NRKH.E181493 & NRKH7.E181493
        1) ≤ 100 mA (PUSH); ≥ –100 mA (PULL).
        2) Voltage output.
        3) At 25 ° C, linearity error (maximum deviation) depending on response curve and minimal deviation function.
        4) At 25 ° C, repeatability magnet movement in one direction.
        5) The analog measured value can deviate under transient conditions.
    Safety-related parameters
    MTTFD	244 years
    DCavg	0 %
    TM (mission time)	20 years
    Communication interface
    Communication interface	IO-Link V1.1
    Communication Interface detail	COM3
    Cycle time	1 ms
    Process data length	16 Bit
    Process data structure	
    Bit 0 = switching signal QL1
    Bit 1 = switching signal QL2
    Bit 2 = switching signal QL3
    Bit 3 = switching signal QL4
    Bit 4 ... 15 = position (in 50 μm)
                Terms and Conditions
                30-day money-back guarantee
                Shipping: Contact us info@aarkautomation.com
            
Once the user has seen at least one product this snippet will be visible.